Fuside PL7105 Piercing Thermal Resistance - Sterilizer Mobile Thermal Resistance
In the production of pharmaceuticals for liquid preparations, sterilization is required to ensure the quality of their products. Sterilization cabinets are a very important equipment in the production of pharmaceuticals. The steam sterilizer (pulsating vacuum sterilizer) uses high-pressure moist steam sterilization, which uses the latent heat in the high-temperature steam to rapidly raise the temperature of the sterilized article, so that the microbial protein is denatured and solidified, thereby achieving the extinction. The effect of the bacteria is that the sterilization process is: pulsation-heating-sterilization-exhaust-drying-end. In the steam sterilization process, the temperature inside the cabinet needs to be monitored. The temperature inside the sterilizer directly affects the safety, effectiveness and stability of the drug efficacy. The following are the conditions for a certain type of medicine to be sterilized in a sterilizer: Sterilization temperature: 121 ° C (121 ° C ~ 125 ° C); Sterilization pressure: 3 bar; Sterilization time: 45 min; Under this condition, the following requirements are imposed on the temperature sensor in the sterilizer: 1. Measurement range and accuracy: The temperature sensor measurement range is -50-150 °C, and the measurement accuracy must meet the A-level requirements; 2, stability and consistency requirements: single-degree repeatability of 0.5 °C within high temperature measurement, the error between different sensors must be less than 1 °C; 3. Sealing requirements: In high temperature and high pressure environment, the sensor requires absolute sealing to prevent water vapor from intruding into the sensor, affecting its stability or damaging the sensor; 4, material requirements: temperature sensor protection tube, connecting cable and other materials are in line with GMP, FDA and other standards, and anti-oxidation, acid and alkali corrosion; Only when the above requirements are met can the disinfection and sterilization effect be ensured, and the drug can be protected from damage, ensuring the safety, effectiveness and stability of the drug. For the measurement of the temperature of the sterilizer, the company introduced a high precision, high stability PL7105 piercing thermal resistance: PL7105 piercing thermal resistance features: 1. Imported PT100 thermal resistance is adopted to ensure the stability and reliability of all assembly parts through aging screening process; the measurement accuracy is higher than A grade (<0.3 °C) and the repeatability is high (<0.5 °C); 2, protective tube material: 316L, in line with GMP, FDA and other standards; pierced end 25 ° sharp angle, easy to penetrate the inside of the drug; 3. The core body is fully insulated from the stainless steel casing to ensure the safety and stability of the measurement process; 4, stainless steel handle and cable are sealed by double crimping process; jacket silicone sheath and cable secondary silica gel filling and sealing; 5, using imported silica gel custom cable, good flexibility, long-term tolerance to -50-150 ° C working environment, passed the antioxidant, salt spray test; PL7105 penetration heat resistance application field: Steam sterilizer (pulsating vacuum steam sterilizer), water bath sterilizer and other wet heat sterilization equipment. Dietary supplements take vitamins, minerals and extracts with relatively clear structure-activity relationship as the main raw materials, and supplement the necessary nutrients and biologically active substances for the human body through oral intake to achieve the purpose of improving the body's health and reducing the risk of disease. Available in concentrated forms such as doses or capsules. Foods in traditional form with added nutrients or biologically active substances. Dietary supplement,New Dietary Ingredient,Dietary Supplement Product,Food Supplements YT(Xi'an) Biochem Co., Ltd. , https://www.ytwholefood.com