Maintenance of small single punching machine
These test kits are new to the market and rely on the detection of viral proteins in swab samples They consist of monoclonal antibodies specific for the viral antigens and results are seen by the naked eye by way of chromatographic particles. There have only been a few of these tests commercialized and normally require a high viral count to work effectively. In the first few months of the pandemic some national health authorities questioned the reliability of these tests, as they usually require a higher viral count that qPCR to show positive. Therefore, false-negatives can occur. antigen test kit, rapid antigen test kit, covid-19 antigen test, antigen detection, antigen rapid test kit Shenzhen Uni-medica Technology Co.,Ltd , https://www.unimed-global.com
Before each shift, check whether the screws of the tablet press are loose. During the work, you should always pay attention to the inspection. If it is loose, tighten it immediately to avoid malfunction.
Before each shift and after each shift, you must manually test a few pieces, and then pass the voltage chip after no problem.
The quality of the die must be checked frequently during the tableting process. If any edge, crack, deformation or severe wear is found, it should be replaced in time to avoid malfunction, damage the machine and affect the quality of the tablet.
The single punching machine is kept clean every day, especially the pressure parts, the ejector pins and the connecting rod parts. After each work, carefully clean the materials remaining on the hopper trolley, the auxiliary hopper, the middle template, the powder removing box, the upper, middle and lower dies to avoid the materials for the next work, so as not to be mixed with the materials for the next work. .
The wear defects of the single punching machine die should be replaced in time. Carefully check whether there are pits on the edge of the middle die. The impact marks of the upper and lower molds should be adjusted or replaced in time. If the machine is not used for a long period of time, the mold should be removed and stored.
Each electrical component of the single punching machine should be inspected before starting. For example, if the inverter has faulty wiring, especially if the power input terminal and output terminal of the inverter are misconnected, whether the input power supply meets the rated standard, and whether there is a short circuit. Check that the terminals are tight and kept intact and normal.