Submersible pump failure phenomenon and troubleshooting

First, the submersible pump failure phenomenon and troubleshooting methods

The submersible pump does not produce water, indirect water, or insufficient water.

1. Check the motor. Check whether the motor has started. If it is not started, check the motor circuit to eliminate the circuit fault. See if the motor circuit is connected correctly, check whether the electric pump is reversed, the electric pump is reversed, and the power cord can be exchanged.

2. Check the pipeline. Look at the pipeline for blockage, rupture, and whether the water filter is blocked. If the pipeline is broken, it should be repaired or replaced, and the blockage should be removed. The fault can be eliminated.

3. Check the seal of the pump casing and check if the impeller is damaged. Remedy: Replace the new seal and impeller.

Second, the motor can not be started with a click

1. Check the motor circuit, if there is a phase disconnection, check the voltage, and whether the voltage is too low. After the circuit is repaired and the voltage is adjusted properly, the fault can be eliminated.

2. Check if there are foreign objects in the impeller, whether the bearing is damaged, eliminate foreign objects or replace the bearing.

Third, the current is too large, the ammeter pointer swings

1. When purchasing a new pump, the reason is that the shaft is bent and the bearings are not concentric, and it is immediately returned to the sales department or manufacturer.

2. Check if the thrust bearing is seriously worn and whether the impeller and the seal ring have friction marks. Replacement method, replace the thrust bearing or thrust disc, the impeller can no longer rub with the seal ring when rotating.

3. Check whether the relative rotation of the shaft and the shaft is flexible. When the rotation is not flexible, the bearing should be replaced or repaired.

4. The moving water level drops below the water inlet. The flow should be reduced or well replaced.

4. Vibrating vibration when the unit is running

1. Check if the connecting bolt is loose and tighten the bolt.

2. After the motor rotor is unbalanced, the pump impeller is unbalanced, the motor or the pump shaft is bent, etc., it should be sent to the manufacturer for processing.