How to correctly install the electric furnace / muffle furnace

How to correctly install the electric furnace/muffle furnace 1. After opening the package, check whether the box type resistance furnace is intact and the accessories are complete. A typical box-type resistance furnace does not require special installation and needs to be placed flat on a flat floor or shelf. The controller should avoid vibration, and the placement position should not be too close to the box type resistance furnace to prevent the internal components from working properly due to overheating.

2. A thermocouple is inserted into the furnace 20-50mm, and the gap between the hole and the thermocouple is filled with asbestos rope. Connect the thermocouple to the control Zui to use the compensation wire (or use insulated steel core wire), pay attention to the positive and negative poles, do not reverse.

3. An additional power switch is required at the power line lead to control the main power supply. In order to ensure safe operation, the box resistance furnace and the controller must be reliably grounded.

4. Before use, adjust the thermometer indicator to zero point. When using the compensation wire and cold end compensator, adjust the mechanical zero point to the reference temperature point of the cold end compensator. When the compensation wire is not used, the mechanical zero point is used. Adjusted to zero scale, but the temperature indicated is the temperature difference between the measurement point and the cold junction of the thermocouple.

5. After checking the wiring and confirming it is correct, cover the controller casing. Adjust the temperature indicator's setting pointer to the desired operating temperature and then turn on the power. Turn on the power switch. At this time, the green light on the meter indicates that the green light is on, the relay starts to work, the box resistance furnace is energized, and the current meter displays current. As the internal temperature of the box-type resistance furnace increases, the temperature indicator meter pointer also rises gradually. This phenomenon indicates that the system is working normally. The temperature rise and constant temperature of the box type resistance furnace are respectively indicated by the traffic light of the temperature indicator, the green light indicates the temperature rise, and the red light indicates the constant temperature.

Plant Growth Regulator

Natural Field strives to develop low toxicity and environmentally friendly agricultural raw materials. They are popular in Europe and North America. We are proud of us: 5-ala, Physcion, Genistein and Triacontanol Etc.


Eg:1. 5-ala: 5-ALA (CAS: 5451-09-2) is suitable for a wide range of scientific fields, such as increasing harvest yield or increasing plant green. Supplementary studies from animal cultures of

2.Physcion emodin methyl ether is extremely toxic to humans and animals, environmentally friendly, and is especially suitable for biological preparations for green and organic vegetable production, as the Plant Growth Regulator Powder.

Plant Growth Regulator,Plant Growth Regulator Powder,Plant Growth Regulator Extract,Plant Growth Regulator Raw Material

Xi'an Natural Field Bio-Technique Co., Ltd. , https://www.naturalfieldfactory.com